AC/DC refrigerators and freezers > internal cooling units
The refrigerators with internal cooling units are easy to install because the cooling unit is mounted directly onto the refrigerator cabinet. These units are recommended in all applications where there is sufficient ventilation around the refrigerator, especially behind it, near the cooling unit. A full range of accessories allows many different custom installations.C39iS - C39iSAC

Volume (Cu Ft)
1.3Weight (Lbs)
38.5C39iS Power voltage (Vdc)
12/24C39iSAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C39iS - C39iSAC Volume Refrigerator compartment (Cu Ft) 1.3 Freezer compartment (Cu Ft) 0.1 freezer internal size Height (Inches) 2.8 Width (Inches) 9.7 Depth (Inches) 8.3 Weight Lbs 38.5 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.10/1.05 Nominal input (W) 27.57 Absorption power (kW 24h ) 0.26 Technical features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.26/0.12 Nominal input (W) 28.9 Absorption power (kW 24h ) 0.27 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Surface flange C51i - C51iAC

Volume (Cu Ft)
1.8Weight (Lbs)
39.6C51i Power voltage (Vdc)
12/24C51iAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C51i - C51iAC Volume Refrigerator compartment (Cu Ft) 1.8 Freezer compartment (Cu Ft) 0.1 Freezer internal size Height (Inches) 2.8 Width (Inches) 9.7 Depth (Inches) 9.1 Weight Lbs 39.6 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.47 Technical features (ac) Power Voltage (V) 100-240 50/60Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.49 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Opening type Front opening • Mounting options Flush flange Bottom trim piece optional C51iS - C51iSAC

Volume (Cu Ft)
1.8Weight (Lbs)
39.6C51iS Power voltage (Vdc)
12/24C51iSAC Power voltage
Vdc 12/24 - vac 100-240 - 50/50 HzModel C51iS - C51iSAC Volume Refrigerator compartment (Cu Ft) 1.8 Freezer compartment (Cu Ft) 0.1 Freezer internal size Height (Inches) 2.8 Width (Inches) 9.7 Depth (Inches) 9.1 Weight Lbs 39.6 Techincal features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.47 Techincal features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.49 Internal cooling unit • External cooling unit Standard - optional Interchangeable door S Magnetic closure S Holding plate version Internal light S Door finish Interchangeable door MDF panel S Opening type Front opening • Top loading fridge Mounting options Surface flange C60i - C60iAC

Volume (Cu Ft)
2.1Weight (Lbs)
48.5C60i Power voltage (Vdc)
12/24C60iAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C60i - C60iAC Volume Refrigerator compartment (Cu Ft) 2.1 Freezer compartment (Cu Ft) 0.4 Freezer internal size Height (Inches) 4.1 Width (Inches) 15.4 Depth (Inches) 9.8 Weight Lbs 48.5 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.32 Technical features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.33 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Flush flange Bottom trim piece optional C62i - C62iAC

Volume (Cu Ft)
2.2Weight (Lbs)
46.5C62i Power voltage (Vdc)
12/24C62iAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C62i - C62iAC Volume Refrigerator compartment (Cu Ft) 2.2 Freezer compartment (Cu Ft) 0.4 Freezer internal size Height (Inches) 4.1 Width (Inches) 15.4 Depth (Inches) 9.8 Weight Lbs 46.5 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.32 Technical features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.33 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Flush flange Bottom trim piece optional C62iS - C62iSAC

Volume (Cu Ft)
2.2Weight (Lbs)
46.5C62iS Power voltage (Vdc)
12/24C62iSAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C62iS - C62iSAC Volume Refrigerator compartment (Cu Ft) 2.2 Freezer compartment (Cu Ft) 0.4 Freezer internal size Height (Inches) 4.1 Width (Inches) 15.4 Depth (Inches) 9.8 Weight Lbs 46.5 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.32 Technical features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.33 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Holding plate version • Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Surface flange C85i - C85iAC

Volume (Cu Ft)
3.2Weight (Lbs)
58.2C85i Power voltage (Vdc)
12/24C85iAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C85i - C85iAC Volume Refrigerator compartment (Cu Ft) 3.2 Freezer compartment (Cu Ft) 0.4 Internal max. size ice area Height (Inches) 5.1 Width (Inches) 15.6 Depth (Inches) 9.8 Weight Lbs 58.2 Techincal features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.36 Techincal features (ac) Power Voltage (V) 100-240 - 50/60Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.37 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Flush flange Bottom trim piece optional C90i - C90iAC

Volume (Cu Ft)
3.1Weight (Lbs)
51.8C90i Power voltage (Vdc)
12/24C90iAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C90i - C90iAC Volume Refrigerator compartment (Cu Ft) 3.1 Freezer compartment (Cu Ft) 0.3 Freezer internal size Height (Inches) 5 Width (Inches) 15.4 Depth (Inches) 7.9 Weight Lbs 51.8 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 36.29 Absorption power (kW 24h ) 0.36 Technical features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.35/0.16 Nominal input (W) 38.1 Absorption power (kW 24h ) 0.37 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Flush flange Bottom trim piece optional C115i - C115iAC

Volume (Cu Ft)
4.2Weight (Lbs)
63.5C115i Power voltage (Vdc)
12/24C115iAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C115i - C115iAC Volume Refrigerator compartment (Cu Ft) 4.2 Freezer compartment (Cu Ft) freezer internal size Height (Inches) 4.7 Width (Inches) 16.5 Depth (Inches) 13.4 Weight Lbs 63.5 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 29.03 Absorption power (kW 24h ) 0.36 Technical features (ac) Power Voltage (V) 100-240 - 50/60 Hz Rated current (A) 0.28/0.13 Nominal input (W) 30.48 Absorption power (kW 24h ) 0.37 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading Mounting options Flush flange Bottom trim piece optional * Crisper bin is a standard part C115iRE - C115iREAC

Volume (Cu Ft)
4.2Weight (Lbs)
63.5C115iRE Power voltage (Vdc)
12/24C115iREAC Power voltage
Vdc 12/24 - Vac 100-240 - 50/60 HzModel C115i RE- C115iREAC Volume (Cu Ft) 4.2 Weight Lbs 63.5 Technical features (dc) Power Voltage (V) 12/24 Rated current (A) 2.80/1.40 Nominal input (W) 29.03 Absorption power (kW 24h ) 0.36 Technical features (ac) Power Voltage (V) 100-240 - 50/60Hz Rated current (A) 0.28/0.13 Nominal input (W) 30.48 Absorption power (kW 24h ) 0.37 Internal cooling unit • External cooling unit Standard - optional Interchangeable door standard Magnetic closure standard Internal light standard Door finish Interchangeable door MDF panel standard Opening type Front opening • Top loading fridge Mounting options Flush flange Bottom trim piece optional * Crisper bin is a standard part
| 1 2 >> |